A Comparative Analysis of TLCD-Equipped Shear Buildings under Dynamic Loads

Document Type : Research Paper

Authors

University of Brasilia, Department of Civil and Environmental Engineering Campus Darcy Ribeiro, Brasilia-DF, 70919-970, Brazil

Abstract

This study targets the behavior of shear buildings equipped with tuned liquid column dampers (TLCD) which attenuate dynamic load-induced vibrations. TLCDs are a passive damping system used in tall buildings. This kind of damper has proven to be very efficient, being an excellent alternative to mass dampers. A dynamic analysis of the structure-damper system was made using the software DynaPy, developed in the research process. The software solves the equations of motion through numeric integration using the central differences method. The simulations results obtained with DynaPy showed that the use of TLCD can reduce the dynamic response significantly for both harmonic excitations and random excitations.

Keywords

Main Subjects

[1] Blevins, R., Flow-Induced Vibration, Krieger Publishing Company, 1990.
[2] Chopra, A., Dynamics of Structures Theory and Application to Earthquake Engineering, Prentice Hall, New Jersey, 1995.
[3] Clough, R., Penzin, J., Dynamics of Structures, Computers and Structures, Incorporated, Berkeley, 2003.
[4] French, A., Vibrações e Ondas, Editora Universidade de Brasília, Brasília, 2001.
[5] Naudascher, E., Rockwell, D., Flow-Induced Vibrations: An Engineering Guide, Dover, 2005.
[6] Pedroso, L., Publicação Didática (Parte I) – Introdução a Dinâmica de Estruturas, University of Brasília, 2000.
[7] Pedroso, L., Interação Fluido-Estrutura (Notas de Aula e Apostila Interna de Curso); versão preliminar, University of Brasília, 2003.
[8] Pedroso, L., Formulação das Equações de Movimento e Determinação das Frequências Naturais para SS1GL, University of
[9] Tedesco, J., McDougal, W., Ross, C., Structural Dynamics: Theory and Applications, Addison Wesley Longman, 1999.
[10] Baleandra, T., Wang, C. M., Rakesh, G., Effectiveness of TLCD on various structural systems, Engineering Structures, 21, 1999, 291-305.
[11] Freitas, M. R., Pedroso, L. J., Rotinas Computacionais em Python para o Estudo do Compotamento de Amortecedores de Líquido Sintonizado na Atenuação de Vibrações em Estruturas, Revista Interdisciplinar de Pesquisa em Engenharia, 2(26), 2016, 1-6.
[12] Freitas, M., Rotinas Análise Dinâmica de Edifícios Equipados com Amortecedores de Líquido Sintonizado ASsistida pelo Software DynaPy, Undergraduate Thesis, Department of Civil and Environmental Engineering, University of Brasília, Brasília, Brazil, 2017.
[13] Gao, H., Kwok, K. C. S., Samali, B., Optimization of tuned liquid, Engineering Structures, 19(6), 1996, 476-486.
[14] Kenny, A., Broderick, B., McCrum, D. P., Optimization of a Tuned Liquid Column Damper for Building Structures, Recent Advances in Structural Dynamics, Pisa, Italy, 2013.
[15] Pedroso, L., Analogia Mecânica para um Estudo de uma Coluna Oscilante de Fluido Incompressível Comportando Efeitos de Rigidez e Dissipação, University of Brasília, 1992.
[16] Pestana, I. G., Controlo de Vibrações em Engenharia Civil - Amortecedor de Colunas de Líquido Sintonizado, Undergraduate Thesis, Faculdade de Ciências e Tecnologia, Universidade Nova de Lisboa, Lisboa, Portugal, 2012.
[17] Shum, K. M., Xu, Y. L., Guo, W. H., Wind-induced vibration control of long span cable-stayed bridges using multiple pressurized tuned liquid column dampers, Journal of Wind Engineering and Industrial Aerodynamics, 96, 2008, 166-192.