Investigation of Pulsatile Blood Flow Dynamics in Anterior Cerebral Artery Aneurysms under Different Physiological Conditions: Hemodynamic Analyses

Document Type : Research Paper

Authors
1 Department of Mechanical Engineering, Iranian Research Organization for Science and Technology (IROST), Tehran, Iran
2 Department of Electromechanical Engineering, C-MAST-Center for Mechanical and Aerospace Science and Technology, Universidade da Beira Interior, Covilha, Portugal
3 School of Mechanical Engineering, Tianjin University, Tianjin, China
Abstract
This computational study investigates how sac volume influences rupture risk in anterior cerebral artery (ACA) aneurysms under different physiological conditions. Three representative body states—rest, normal activity, and sport—are modeled to quantify their effects on key hemodynamic parameters associated with aneurysm stability. Patient-specific geometries are simulated using the transient Navier–Stokes equations with the Casson non-Newtonian model to accurately capture the shear-thinning behavior of blood. Wall shear stress (WSS) and oscillatory shear index (OSI) are evaluated throughout the cardiac cycle to characterize flow-induced mechanical loading on the aneurysm wall. The results demonstrate that although larger aneurysms exhibit higher internal velocities, their broader ostium areas distribute inflow more uniformly, producing smaller localized high-risk regions. In contrast, smaller aneurysms experience sharply concentrated WSS at the ostium due to restricted inflow, generating focal zones of elevated mechanical fatigue that may predispose them to rupture. The dome of large aneurysms remains the dominant high-pressure and high-WSS region, whereas the neck region governs rupture-related stress patterns in small aneurysms. Furthermore, while changes in body physiology significantly alter flowrate and WSS magnitudes, OSI values in large aneurysms remain relatively stable, indicating reduced susceptibility to oscillatory flow disturbances. These findings highlight the coupled roles of sac volume and physiological state in shaping aneurysm hemodynamics and provide improved mechanistic insight into size-dependent rupture risk.
Keywords
Subjects

Publisher’s Note Shahid Chamran University of Ahvaz remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.

[1] Rostamian, A., Fallah, K., Rostamiyan, Y., Reduction of rupture risk in ICA aneurysms by endovascular techniques of coiling and stent: Numerical study, Scientific Reports, 13(1), 2023, 7216.
[2] Sadeh, A., Kazemi, A., BahramKhoo, M., Barzegar Gerdroodbary, M., Computational analysis of the blood hemodynamic inside internal cerebral aneurysm in the existence of endovascular coiling, International Journal of Modern Physics C, 34(05), 2023, 2350059.
[3] Mousavi, S.V., Barzegar Gerdroodbary, M., Sabernaeemi, A., Salavatidezfouli, S., Valipour, P., Impacts of the aneurysm deformation induced by stent on hemodynamic of blood flow in saccular internal carotid artery aneurysms, AIP Advances, 14(9), 2024, 095035.
[4] Chen, S.T., Boddicker, N.J., Maurer, M.J., Allmer, C., Robinson, D.P., Nowakowski, G., Habermann, T.M., Slager, S.L., Thompson, C.A., Cerhan, J.R., Genetic Risk Factors for Cardiovascular Disease in Adult Lymphoma Patients, Blood, 134, 2019, 5215.
[5] Shiryanpoor, I., Kheiri, A., Gerdroodbary, M.B., Valipour, P., Moradi, R., Using computational fluid dynamic for evaluation of rupture risk of micro cerebral aneurysms in the growth process: Hemodynamic analysis, International Journal of Modern Physics C, 36(02), 2025, 2450184.
[6] Zaman, A., Ali, N., Khan, A.A., Computational biomedical simulations of hybrid nanoparticles on unsteady blood hemodynamics in a stenotic artery, Mathematics and Computers in Simulation, 169, 2020, 117-132. 
[7] Najafi, N., Almosawy, W., Abbas, M.S., Goligerdian, A., Najafi, M., Abdi, N., Ardalan, A., Aminian, S., Comparative analysis of the silver-gold and copper-titanium dioxide hybrid nanoparticles impact on flow and heat transfer of the pulsatile blood in occluded cerebral artery, Journal of Thermal Biology, 127, 2025, 104060.
[8] Hoi, Y., Meng, H., Woodward, S.H., Bendok, B.R., Hanel, R.A., Guterman, L.R, Hopkins, L.N., Effects of arterial geometry on aneurysm growth: three-dimensional computational fluid dynamics study, Journal of Neurosurgery, 101(4), 2004, 676-681. 
[9] Sankaran, S., Grady, L., Taylor, C.A., Impact of geometric uncertainty on hemodynamic simulations using machine learning, Computer Methods in Applied Mechanics and Engineering, 297, 2015, 167-190.
[10] Hassan, T., Timofeev, E.V., Saito, T., Shimizu, H., Ezura, M., Tominaga, T., Takahashi, A., Takayama, K., Computational replicas: anatomic reconstructions of cerebral vessels as volume numerical grids at three-dimensional angiography, American Journal of Neuroradiology, 25(8), 2004, 1356-1365. 
[11] Tateshima, S., Viñuela, F., Villablanca, J.P., Murayama, Y., Morino, T., Nomura, K., Tanishita, K., Three-dimensional blood flow analysis in a wide-necked internal carotid artery—ophthalmic artery aneurysm, Journal of Neurosurgery, 99(3), 2003, 526-533.
[12] Jou, L.D., Wong, G., Dispensa, B., Lawton, M.T., Higashida, R.T., Young, W.L., Saloner, D., Correlation between lumenal geometry changes and hemodynamics in fusiform intracranial aneurysms, American Journal of Neuroradiology, 26(9), 2005, 2357-2363. 
[13] Steinman, D.A., Milner, J.S., Norley, C.J., Lownie, S.P., Holdsworth, D.W., Image-based computational simulation of flow dynamics in a giant intracranial aneurysm, American Journal of Neuroradiology, 24(4), 2003, 559-566. 
[14] Gerdroodbary, M.B., Salavatidezfouli, S., A predictive surrogate model based on linear and nonlinear solution manifold reduction in cardiovascular FSI: A comparative study, Computers in Biology and Medicine, 189, 2025, 109959.
[15] Barzegar Gerdroodbary, M., Salavatidezfouli, S., A predictive surrogate model of blood haemodynamics for patient-specific carotid artery stenosis, Journal of the Royal Society Interface, 22(224), 2025, 20240774.
[16] Sforza, D.M., Putman, C.M., Cebral, J.R., Hemodynamics of cerebral aneurysms, Annual Review of Fluid Mechanics, 41(1), 2009, 91-107.
[17] Fung YC. Biomechanics: mechanical properties of living tissues. 2nd ed. Boston: Springer; 1993.
[18] Rostamian, A., Fallah, K., Rostamiyan, Y., Alinejad, J., Application of computational fluid dynamics for detection of high risk region in middle cerebral artery (MCA) aneurysm, International Journal of Modern Physics C, 34(02), 2023, 2350019.
[19] Cebral, J.R., Mut, F., Weir, J., Putman, C.M., Association of hemodynamic characteristics and cerebral aneurysm rupture, American Journal of Neuroradiology, 32(2), 2011, 264-270.
[20] Sadeh, A., Kazemi, A., Bahramkhoo, M., Barzegar Gerdroodbary, M., Computational study of blood flow inside MCA aneurysm with/without endovascular coiling, Scientific Reports, 13(1), 2023, 4560.
[21] Ding, J., Valipour, P., Impacts of coiling technique on hemodynamic of the MCA aneurysms: Computational study, International Journal of Modern Physics C, 35(05), 2024, 2450057.
[22] Valipour, P., Effects of coiling embolism on blood hemodynamic of the MCA aneurysm: A numerical study, Scientific Reports, 12(1), 2022, 22029.
[23] Barzegar Gerdroodbary, M., Wang, X., A Computational Analysis of Sac Volume Effects on Hemodynamics and Rupture Risk in Cerebral Saccular Aneurysms, Journal of Applied and Computational Mechanics, 2026, DOI: 10.22055/jacm.2025.48445.5236.
[24] Ali, R., Hassan, H.I., Sharma, A., Dhawan, A., Sharma, P., Taher, W.M., Alwan, M., Al-Hussainy, A.F., Mushtaq, H. and Heaie, T., Efficiency of endovascular coiling on the evolution of MCA cerebral aneurysm by hemodynamic analysis: Computational study, International Journal of Modern Physics C, 2025, 2550065.
[25] Haie, T., Ali, R., Albadr, R.J., Sharma, A., Dhawan, A., Sharma, P., Taher, W.M., Alwan, M., Jawad, M.J., Mushtaq, H., Computational analysis of equivalent porous conditions in realistic coiling techniques for hemodynamic evaluation of ICA aneurysms, International Journal of Modern Physics C, 2025, 2550029.
[26] AneuriskWeb project website, http://ecm2.mathcs.emory.edu/aneuriskweb, Emory University, Department of Math & CS, 2012
[27] Ansys, I., ANSYS® Fluent User’s Guide, Release 2020 R2. Canonsburg: ANSYS, 2020.
[28] Voss, S., Beuing, O., Janiga, G., Berg, P., Stent-induced vessel deformation after intracranial aneurysm treatment–A hemodynamic pilot study, Computers in Biology and Medicine, 111, 2019, 103338.
[29] Qin, S., Wu, B., Liu, J., Shiu, W.S., Yan, Z., Chen, R., Cai, X.C., Efficient parallel simulation of hemodynamics in patient-specific abdominal aorta with aneurysm, Computers in Biology and Medicine, 136, 2021, 104652.
[30] Xu, L., Liang, F., Zhao, B., Wan, J., Liu, H., Influence of aging-induced flow waveform variation on hemodynamics in aneurysms present at the internal carotid artery: A computational model-based study, Computers in Biology and Medicine, 101, 2018, 51-60.
[31] Boccadifuoco, A., Mariotti, A., Celi, S., Martini, N., Salvetti, M.V., Impact of uncertainties in outflow boundary conditions on the predictions of hemodynamic simulations of ascending thoracic aortic aneurysms, Computers & Fluids, 165, 2018, 96-115.
[32] Mitsos, A.P., Kakalis, N.M., Ventikos, Y.P., Byrne, J.V., Haemodynamic simulation of aneurysm coiling in an anatomically accurate computational fluid dynamics model, Neuroradiology, 50(4), 2008, 341-347.
[33] Malvè, M., Chandra, S., García, A., Mena, A., Martínez, M.A., Finol, E.A., Doblaré, M., Impedance-based outflow boundary conditions for human carotid haemodynamics, Computer Methods in Biomechanics and Biomedical Engineering, 17(11), 2014, 1248-1260.