Nonlinear Biodynamic Models of the Hand-arm System and ‎Parameters Identification using the Vibration Transmissibility or ‎the Driving-point Mechanical Impedance

Document Type : Research Paper

Authors

Laboratory of Renewable Energy and Dynamics of Systems, Faculty of Sciences Ain Chock, University Hassan II of Casablanca,‎ B.P. 5366 Maarif, Casablanca, 20100, Morocco

Abstract

This study aims at deriving nonlinear expressions of the transmissibility and the driving-point mechanical impedance (DPMI) of two nonlinear biodynamic hand-arm models having active restoring and dissipative parameters. It aims also in computing explicitly the non-directly measurable stiffness and damping coefficients of the human hand-arm system (HAS). Multivariate Padé approximants are used to express the dependence of the HAS mechanical properties on various influencing factors. The harmonic balance method is used to derive analytical expressions of the transmissibility and the DPMI. Then, the models parameters are identified by minimizing constrained error functions between the theoretical DPMI or transmissibility and the measured data. The developed workflow is applied to three experimental data sets of Z-direction vibrations where the excitation frequency and/or the grip force are varied. Using the ISO-10068 (2012) limit DPMI values versus the excitation frequency, we derived upper and lower limits of the overall stiffness coefficient and damping ratio for the human HAS. Furthermore, the model reproduces with high accuracy experimental measurements of the transmissibility, the DPMI and the vibration power absorption.

Keywords

Main Subjects

[1] Griffin, M.J., Handbook of human vibration, Academic Press, London, 1996.
[2] Mansfield, N.J., Human response to vibration, CRC Press, 2004.
[3] Adewusi, S.A., Rakheja, S., Marcotte, P., Boutin, J., Vibration transmissibility characteristics of the human hand-arm system under different postures, hand forces and excitation levels, Journal of Sound and Vibration, 329, 2010, 2953-2971.
[4] Saha, S., Kalra, P., A review on hand-arm vibration exposure and vibration transmissibility from power hand tools to hand-arm system, International Journal of Human Factors and Ergonomics, 4(1), 2016, 10-46.
[5] Aldien, Y., Marcotte, P., Rakheja, S., Boileau, P.E., Influence of hand forces and handle size on power absorption of the human hand-arm exposed to zh-axis vibration, Journal of Sound and Vibration, 290, 2006, 1015-1039.
[6] Dong, J.H., Dong, R.G., Rakheja, S., Welcome, D.E., McDowell, T.W., Wu, J.Z., A method for analyzing absorbed power distribution in the hand and arm substructures when operating vibrating tools, Journal of Sound and Vibration, 311, 2008, 1286-1304.
[7] Reynolds, D.D., Soedel, W., Dynamic response of the hand-arm system to a sinusoidal input, Journal of Sound and Vibration, 21(3), 1972, 339-353.
[8] Lundström, R., Burström, L., Mechanical impedance of the human hand-arm system, International Journal of Industrial Ergonomics, 3, 1989, 235-342.
[9] Pan, D., Xu, X.S., Welcome, D.E., McDowell, T.W., Warren, Ch., Wu, J., Dong, R.G., The relationships between hand coupling force and vibration biodynamic responses of the hand-arm system, Ergonomics, 6(16), 2018, 818-830.
[10] Rakheja, S., Wu, J.Z., Dong, R.G., Schopper, A.W., Boileau, P.E., A comparison of biodynamic models of the human hand-arm system for applications to hand-held power tools, Journal of Sound and Vibration, 249(1), 2002, 55-82.
[11] Dong, R.G., Dong, J.H., Wu, J.Z., Rakheja, S., Modeling of biodynamic responses distributed at the fingers and the palm of the human hand-arm system, Journal of Biomechanics, 40, 2007, 2335-2340.
[12] ISO-10068, Mechanical vibration and shock, mechanical impedance of the human hand-arm system at the driving point, International Organization for Standardization, Geneva, Switzerland, 2012.
[13] Gurram, R., Rakheja, S., Brammer, A.J., Driving-point mechanical impedance of the human hand-arm system: Synthesis and model development, Journal of Sound and Vibration, 180, 1995, 437-458.
[14] Gurram, R., Rakheja, S., Boileau, P.E., Gouw, G.J., Development of a grip force dependent hand-arm vibration model, Central European Journal of Public Health, 4(1), 1996, 65-68.
[15] Marcotte, P., Aldien, Y., Boileau, P.E., Rakheja, S., Boutin, J., Effect of handle size and hand-handle contact force on the biodynamic response of the hand-arm system under zh-axis vibration, Journal of Sound and Vibration, 283, 2005, 1071-1091.
[16] Hida, N., Abid, M., Lakrad, F., A nonlinear model of the hand-arm system and parameters identification using vibration transmissibility, MATEC Web of Conferences, 241, 2018, 01014.
[17] Braess, D., Nonlinear approximation theory, Springer-Verlag, Berlin, 1986.
[18] Guillaume, P., Huard, A., Multivariate Padé approximation, Journal of Computational and Applied Mathematics, 121(1-2), 2000, 197-219.
[19] Nayfeh, A.H., Introduction to perturbation methods, John Wiley and Sons, New-York, 1981.
[20] Burström, L., Measurement of the mechanical energy absorption in the hand and arm whilst using vibrating tools, Journal of Low Frequency Noise and Vibration, 9(1), 1990, 1-14.
[21] Bates, D.M., Watts, D.G., Nonlinear regression and its applications, Wiley, New York, 1988
[22] Gurram, R., A study of vibration response characteristics of the human hand-arm system, Ph.D. Thesis, Department of Mechanical Engineering, Concordia University, Montreal, Quebec, 1993.
[23] Gurram, R., Rakheja, S., Gouw, G.J., Mechanical impedance of the human hand-arm system subject to sinusoidal and stochastic excitations, International Journal of Industrial Ergonomics, 16, 1995, 135-145.
[24] Kefauver, J.M., Ward, A.B., Discoveries in structure and physiology of mechanically activated ion channels, Nature, 587, 2020, 567-576.
[25] Yildirim, M.A., Topkara, B., Aydin, T., Paker, N., Soy, D., Coskun, E., Ones, K., Bardak, A., Kesiktas, N., Ozyurt, M.G., Celik, B., Onder, B., Kilic, Aysegul, Kucuk, H.C., Karacan, Ilhan, Türker, K.S., Exploring the receptor origin of vibration-induced reflexes, Spinal Cord, 58, 2020, 716-723.